Evidence

Validation summaries you can inspect.

Sleep staging · n=120 · AASM 4-stage

Overnight staging vs PSG

Mattress-based sleep-stage output compared with polysomnography reference scoring.

  • 67.5% epoch agreement
  • 78.5% REM sensitivity
  • −2.6 min Total sleep time bias
Open summary
Respiratory events · n=126 · test n=61

Event scoring and AHI

Apnoea and hypopnoea events scored overnight, summarised as AHI against PSG.

  • r = 0.94 model vs PSG AHI
  • 7.3 /hr mean absolute error
  • AUC 0.99 Central apnoea
Open summary
Gold-standard detailed physiology · n=13

Can one mattress signal show how hard you're breathing?

Continuous ventilation and respiratory-effort patterns beyond nightly event counts.

  • r = 0.86 ventilation
  • r = 0.70 respiratory effort
  • Multi-night ventilation burden & effort instability
Open summary
Ventilatory burden · test n=81 · vs nasal-cannula methods

How much of the night is breathing on half power?

Beyond AHI event counts — the share of sleep spent below half of a person’s own breathing baseline.

  • r = 0.92 vs PUP cannula method
  • 81 held-out overnight studies
  • vs PUP / Midflow cannula references
Open summary
Loop gain · lab n=81 · home n=64 · 799 nights

Loop gain, without a wire in sight

Breathing-control stability from under-mattress sensing — ranked against the lab PUP method and tracked at home.

  • r = 0.86 vs standard lab method
  • 72% same low / moderate / high group
  • 6.5% false alarms over 7 nights
Open summary
Arousal threshold · lab n=81 · home n=70 · 803 nights

Respiratory arousal threshold: the alarm in your sleep brain

How hard it is to wake from breathing effort — estimated from the mattress, checked against invasive pressure and PUP.

  • r = 0.92 vs invasive catheter
  • r = 0.82 vs PUP (81 nights)
  • ~1% mislabel risk after 6 nights
Open summary
Vital signs · n=182 · 3 validation studies

Can your mattress read your heartbeat?

Heart rate and breathing rate from under-mattress motion, checked against ECG and airflow.

  • 0.74 bpm still HR MAE
  • 3.41 bpm overnight HR MAE
  • r = 0.78 beat-to-beat median
Open summary

Transparency disclosure

  • On-site research summaries: available
  • Peer-reviewed manuscript / DOI: under review
  • Preprint: not yet linked
  • Protocol registration / ethics reference: not yet linked (add when approved for public listing)
  • Regulatory status: research-stage investigational platform. Not a medical device.

Looking for manuscripts, abstracts, posters or talks? Open Publications